ТЕСТ репорт Вебасто
Ниже привожу тест отчёт вышеупомянутой вебасты.
Diagnosis report WEBASTO
Thermosystems
31.10.13 16:44:27 Webasto Thermo Test 2.14 page 1 of 1
faults on webasto initial
Configuration:
W-Bus version........................................... .......................1.5
Device name.............................................. ....................E1 MAC
Fuel type.............................................. .........................Diesel
Circulating pump in control idle period.........................................0
Heating duration limitation........................................ .............60 [min]
Factor for shortening of ventilation duration...............................1/1
Device identification number............................................ ...09007019A
Dataset identification number............................................ ..09008576C02
HW version........................................... ............................26/3
SW version........................................... .............................29/04
Date of manufacture heater............................................ ......06.03.06
Customer identification number............................................ .3138364C37
Serial number............................................ .......................00055443
Minimum voltage threshold......................................... .........10,51 [V]
Operating data:
---------------
Working hours............................................. ...................19:11 [h:m]
Operating hours............................................. .................81:57 [h:m]
Start count............................................. ........................290
Error:
------
Fault 1................................................. .....Heating unit interlocked
State of fault............................................. .stored, actual
Code.............................................. .............07h
Counter........................................... .............1
Temperature....................................... .........101 [°C]
Operating state............................................. Off state
Любые комментарии приветствуются.
|